Products List
Emergency Training Manikin
Nursing Skill Training Simulator
Maternal & Child Specialist Skills Training Model
Clinical Skill Training Model
Professional Skills Training Model For Clinical Diagnosis
Human Skeleton Model
Anatomy Model
Traditional Chinese Medicine Training Model
Stomatoloy Training Model
Contact us

Shanghai Holian Medical Model Co.,Ltd.
Add: Industrial Comprehensive Development Zone,Shanghai,China,201000.
Tel:0086-4008919098
Mobile Tel: 0086-13585519079
E-mail: sales@holianmodel.com
Website: www.holianmodel.com
HL/CPR550 Advanced CPR Manikin(table computer and wireless conection) Your Current Location:Home > PRODUCTS > Emergency Training Manikin >
HL/CPR550 Advanced CPR Manikin(table computer and wireless conection)

HL/CPR550 Advanced CPR Manikin(table computer and wireless conection)

  • Name:HL/CPR550 Advanced CPR Manikin(table computer and wireless conection)
  • Model:HL/CPR550
  • Item:HLA0028
  • Classification:Emergency Training Manikin
  • Views:

 
Details
Implement standard: American Heart Association(AHA ) 2015 Guideline for Cardiopulmonary Resuscitation(CPR) & Emergency Cardiovascular Care(ECC)
System Features:
1. The upper limb joints are free movable.
2. The manikin can be connected with PAD through Wi-Fi.
3. Vital signs simulation:
1). The pupil is mydriasis,carotid arterial pulseless in original state.
2). The carotid arterial pulse,pulse frequency and compression frequency is consistent during the compression process.
3) The pupil is recover normal and carotid arterial pulse automatically after success rescue.
4. Artificial respiration and external breast compression can be carried out.
5. Standard airway open.
6. Three operation mode:CPR training,evaluation and scene evaluation.
1). Mode 1:CPR training,the inhalation and compression can be carried out in the setting time.
2). Mode 2:assessment,according to the 2015 CPR standard,the ratio of correct compression and inhalation as 30:2,to complete 5 cycle operation.
3) Model 3:according to the 2015 CPR standard,the ratio of correct compression and inhalation as 30:2,to complete 5 cycle operation.
7. Assessment process:emergency call,consciousness awareness,pulse,breath and etc.
Controller Features:
1. Electronic monitoring:the indicate light display the airway open and compression part.The counting of correct and wrong times for artificial respiration and extemal breast compression.
2. Sound indication.
3. Strip indicate light displays inhalation volume:500-600ml-1000ml is the correct inhalation volume.
1). Too less inhalation volume,the strip indicate light displays yellow.
2). Normal inhalation volume,the strip indicate light displays green.
3). Too much inhalation volume,the strip indicate light displays red.
4. Strip indicate light display compression depth:5-6cm is the correct compression intensity.
1). Too less compression,the strip indicate light displays yellow.
2). Normal compression,the strip indicate light displays green.
3). Too much compression,the strip indicate light displays red.
5. The operation time can be set freely.
6. Power status:in-built lithium battery.
7. The operation process can be printed.
8. The report covers the operation mode,the times of compression and inhalation,times of correct and wrong compression and inhalation,time setting,operation time,result evaluation and etc.
Main Components:
1. Full body manikin (1).
2. PAD(1)
3. Plastic case(1).
4. CPR operation pad(1).
5. CPR face shield sheet 50pcs/box (1 box).
6.Replaceable lung bag (5).
7. Replaceable face skin (1).
8. User manual(1).
 
 
Related
 
Copyright:Shanghai Holian Medical Model Co.,Ltd. 沪ICP备17034982号-2 Add:Industrial Comprehensive Development Zone,Shanghai,China,201000.
Mobile Tel: 0086-13585519079 E-mail: sales@holianmodel.com Website: www.holianmodel.com