Product Introduction:
The CPR Manikin has built-in main control board,which can be operated without the display controller.It has voice prompt function and standard lithium battery.It can be used for 2-5 hours without power supply.
Implement standard: American Heart Association(AHA ) 2015 Guideline for Cardiopulmonary Resuscitation(CPR) & Emergency Cardiovascular Care(ECC).
System Features:
1. The upper limb joints are free movable.
2. The manikin has voice prompt function and standard lithium battery.
3. Simulated true pupil light reflection.
4. Vital signs simulation:
1). The pupil is mydriasis,carotid arterial pulseless in original state.
2). The carotid arterial pulse,pulse frequency and compression frequency is consistent during the compression process.
3). The pupil is recover normal and carotid arterial pulse automatically after success rescue.
4). The pupil changes and carotid arterial pulse is control by switch.
5. Artificial respiration and external breast compression can be carried out.Standard airway open and indicate light turns green.
6. Three operation mode:CPR training,assessment and scene evaluation.
Mode 1:CPR training,the inhalation and compression can be carried out.
Mode 2:assessment,according to the 2015 CPR standard,the ratio of correct compression and inhalation as 30:2,to complete 5 cycle operation.
Mode 3:teachers will set the operation time range,operation standard,cycle times,operation frequency,the ratio of compression and inhalation.
Controller Features:
1. Electronic monitoring:the indicate light display the airway open and compression part.The counting of correct and wrong times for artificial respiration and external breast compression.
2. Sound indication.
3. Strip indicate light displays inhalation volume:500~600ml-1000ml is the correct inhalation volume.
1). Too less inhalation volume,the strip indicate light display yellow.
2). Normal inhalation volume,the strip indicate light display green.
3).Too much inhalation volume,the strip indicate light display red.
4).Inhalation too quickly or too much result in air entering into stomach,indicate light display,digital counter display and sound prompting.
4. Strip indicate light display compression depth:5-6cm is the correct compression intensity.
1). Too less compression,the strip indicate light displays yellow.
2). Normal compression,the strip indicate light displays green.
3). Too much compression,the strip indicate light displays red.
5. The accuracy rate of the operation can be set freely.
6. The operation time can be set freely.
7. Operation frequency:100-120 times per minute.
8. Power status:adopt 220V external power,the output power is 12V through voltage stabilizer.
Printer Features:
1. Operation process can be printed.
2. The report covers the operation mode,the times of compression and inhalation,times of correct and wrong compression and inhalation,time setting,operation time,result evaluation and etc.
Main Components:
1. Full body manikin (1).
2. Power adapter (1).
3. Portable plastic box (1).
4. CPR operation pad (1).
5. CPR face shield sheet (50pcs/box).
6. Exchangeable lung bag (5).
7. Exchangeable face skin (3).
8. User manual (1).